High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
75379.11 USD
Terms of Payment
LC, T/T, D/P, Western Union
  • High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body
  • High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body
  • High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body
  • High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body
  • High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body
  • High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
CY-MSG-DCRF-TR-M
Type
High Pressure Vertical Tube Furnace
Certification
CE
Structure
Vertical Type
Brand
Cyky
Max. Temperature
500c Max
Sputtering Gun
2 Inches
Product Name
Magnetron Sputtering Coater
Vacuum Pump
Turbo Vacuum Pump Set
Pump Speed
600L/S
Target Gun Diameter
2 Inches
Vacuum Level
5*10-4PA
Transport Package
Wooden Case
Specification
high pressure vertical tube furnace
Trademark
CYKY
Origin
China
HS Code
85141090
Production Capacity
500 Sets Per Month

Product Description

Product Description

 

Brief introduction of the magnetron sputtering system:

 

this equipment is dual target magnetron sputtering coater apparatus, which can be used for the preparation of metal thin films. It has applications in the fields of electronics, optics, and special ceramic preparation. It can also be used for laboratory SEM sample preparation. 

 

Product Parameters

Specification of the Dual-Head High Vacuum 2" Magnetron Plasma Sputtering Coater system

 

 

Product name

Double   target magnetron sputtering coater with transition chamber

Product model

CY-MSP325G-2T-DVC-2DC(double vacuum chamber)

Installation   conditions

1.   Operating environment temperature 25ºC±15ºC, humidity 55%Rh±10%Rh;

2.   Equipment power supply: AC220V, 50Hz, must be well grounded;

3.   Rated power: 5000w;

4.   Equipment gas: the equipment chamber needs to be filled with argon for   cleaning, and the customer needs to prepare argon, with a purity of ≥99.99%;

5. The   size of the venue is 1200mm×1200mm×2000mm;

6. The   placement position requires good ventilation and heat dissipation.

Technical   parameters

1.   Sputtering power supply: DC power supply 500W x2; maximum output voltage   600V, limit output current 1000mA

2.   Magnetron target: 2-inch balanced target with magnetic coupling baffle;

3.   Applicable target material for magnetron target: φ50mm x 3mm thick conductive   metal target material

4.   Cavity size: main cavity φ325mm x 410mm; transition cavity 150x150x150mm

5.   Chamber function: The main chamber is equipped with a side door sealed by a   sealing ring, a quartz observation window with a baffle, and a manual   operating rod for transferring samples. The transition chamber is equipped   with an upper cover with a quartz window sealed by a sealing ring, a magnetic   coupling push rod for transporting samples into the main chamber, and an   independent vacuum system.

6.   Cavity material: stainless steel 304

7.   Rotating heating sample table: The speed is continuously adjustable from 1 to   20 rpm; the heating temperature is up to 500°C, and the heating rate is   recommended to be 10°C/min, and the maximum temperature is 20°C/min.

8.   Cooling method: Magnetron target and molecular pump need circulating water   cooler;

9.   Water cooler: water tank volume 9L, flow rate 10L/min

10. Gas   supply system: mass flow meter, gas type AR gas, flow   rate 1~200sccm (customizable);

11. Flow   meter accuracy: ±1.5% range

12. The   pumping interface of the vacuum chamber is CF160;

13. The   air inlet interface is a 1/4 inch double ferrule joint;

14. The   display is 14 industrial computer all-in-one computers;

15. The   sputtering current can be adjusted, and the sputtering safe current value and   safe vacuum value can be set;

16.   Safety protection: Sputtering current will be automatically cut off when   overcurrent and vacuum are too low;

17.   Vacuum system: the main chamber is equipped with a CY-GZK103 high vacuum   molecular pump set with a pumping speed of 600L/s; the transition chamber is   equipped with a small molecular pump set with a pumping speed of 60L/s. The   two sets of vacuum systems can work and control independently, and the   pneumatic valves between the chambers and in the vacuum system are all   controlled by programs, which can realize one-key action, which is convenient   and quick.

18. Ultimate   vacuum: 5E-4Pa (with molecular pump);

19. The   vacuum measurement is a composite vacuum gauge, and its range is:   10-5Pa~105Pa

Precautions

1. In   order to achieve a higher oxygen-free environment, the vacuum chamber must be   cleaned with high-purity inert gas at least 3 times.

2.   Magnetron sputtering is more sensitive to the intake air volume, and a mass   flow meter needs to be used to control the intake air volume.

3. Keep   the cavity in a vacuum when the equipment is not in use.

4. If   it has not been vacuumed for a long time, it should be degassed when it is   used again to improve the vacuum performance.

Optional   accessories

Film   thickness monitor

1. Film   thickness resolution: 0.0136Å (aluminum)

2. Film   thickness accuracy: ±0.5%, depending on the process conditions, especially   the position of the sensor, material stress, temperature and density

3.   Measurement speed: 100ms-1s/time, the measurement range can be set: 500000Å   (aluminum)

4.   Standard sensor crystal: 6MHz

5.   Applicable chip frequency: 6MHz Applicable chip size: Φ14mm Mounting flange:   CF35

Other   accessories

1.   CY-CZK103 series high-performance molecular pump set (including compound   vacuum gauge, measuring range 10-5Pa~105Pa);

CY-GZK60   series small molecular pump set (including compound vacuum gauge, measuring   range 10-5Pa~102Pa)

VRD-4   bipolar rotary vane vacuum pump;

2.   KF25/40 vacuum bellows; length can be 0.5m, 1m, 1.5m; KF25 clamp bracket

3.   Crystal oscillator of film thickness meter;


 

Detailed Photos

High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber BodyHigh Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber BodyHigh Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body

High Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber BodyHigh Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber BodyHigh Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber BodyHigh Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber BodyHigh Vacuum Magnetron Sputtering Coater with Transmission and Samples Chamber Body

Company Profile

Zhengzhou CY Scientific Instrument Co., Ltd.- is a high and new technology enterprise registered in Zhengzhou,Henan province. Zhengzhou CY Scientific Instrument Co., Ltd is mainly engaged in researching and developing, designing and manufacturing of equipment used in scientific researches.
Our mainly products include high temperature furnace and heating element, like lab muffle furnace, tube furnace, dental furnace, vacuum furnace,gold melting furnace, SiC heating element, MoSi2 heating element, alumina tubes and crucibles, and etc.



 

 


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier