Customization: | Available |
---|---|
Type: | Ceramic Heating Equipment |
Certification: | CE, TUV |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Power | Voltage | 220V 50HZ three phase | 220V 50HZ three phase |
Rated Power | 13KW | 15KW | |
Microwave system | Microwave output power | 0.01-4.20KW Continuously adjustable |
0.01-5.60KW Continuously adjustable |
Microwave frequency | 2.45GHZ+/-25MHZ | 2.45GHZ+/-25MHZ | |
Thermal insulation system | Ultimate temperature | 1600C | 1600C |
Continuously working temperature | 1550C | 1550C | |
Heating zone | 150x120mm(Dia.x Height) | 180x150mm(Dia.x Height) | |
Heating rate | Average heating rate >=40C/min. | Average heating rate is >=40C/min. | |
Temperature control system | Temperature measurement method | Infrared thermometer | Infrared thermometer |
Temperature measurement range | 300-1800C | 300-1800C | |
Temperature control precision | +/-0.5% | +/-0.5% | |
Atmosphere system | Static ultimate vacuum degree | =< 10-3Pa | =< 10-3Pa |
Control system | Automatically,manually, Thermostatically control system,PLC+Touch Screen |
40 segments of programmable technical parameters;data storage and export;curve data in real-time display;dynamic data display,one click autostart high vacuum condition | 40 segments of programmable technical parameters;data storage and export;curve data in real-time display;dynamic data display,one click autostart high vacuum condition |
Atmosphere system | Vacuum system,two way atmosphere control circuit | Quick pre-vacuum pumping,atmosphere options,oxidizing gas,inert gas,weak reducing gas,etc. | Quick pre-vacuum pumping,atmosphere options,oxidizing gas,inert gas,weak reducing gas,etc. |
Rotary sealing | Magnetic fluid | ||
Mute oil free compressor | 0.4-0.7MPa | 0.4-0.7MPa | |
Safety system | Microwave leakage prevention | Microwave leakage intensity<0.1mW/cm2 | Microwave leakage intensity<0.1mW/cm2 |
Magnetron alarm | Built-in over temperature alarm,over-current alarm | Built-in over temperature alarm,over-current alarm | |
Furnace door protection alarm | Furnace door shutdown protection switch | Furnace door shutdown protection switch | |
Cooling Water Flow Alarm | Flow alarm | Flow alarm | |
Cooling system | High precision cooling water machine | Flow rate 2m3/h;rated cooling capacity 5.2KW | Flow rate 2m3/h;rated cooling capacity 7.2KW |
Overall dimension | Main furnace | About 2100x2200x2000mm(LxWxH) | About 2100x2200x2000mm(LxWxH) |
Floor space | About 5m2 | About 5m2 |