• DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor
  • DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor

DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor

Customized: Customized
Structure: Desktop
Material: Stainless Steel
Certification: CE, TUV
Application: Lab
Type: Measurement Type
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
CY-VTC-600-2HD
DC Source
500W
RF Source
600W
Vacuum Chamber
Stainless Steel
Gas Flow Control
Mass Flow Meter
Warranty
One Year
Transport Package
Wooden Box
Specification
300 mm Dia x 300 mm height
Trademark
CY
Origin
Zhengzhou, China
HS Code
85141090
Production Capacity
120 Sets/Month

Product Description

Dual-Head Magnetron Plasma Sputtering system  / Magnetron Sputter Coater
Brief introduction

VTC-600-2HD is a compact magnetron sputtering system with dual 2" target sources, e.g., one DC source for coating metallic film, and another RF source for coating non-metallic material. A film thickness tracker is included to enable the user to control processing easily. This coater is designed for coating both single or multiple film layers for a wide range of materials, such as alloy, ferroelectric, semiconductor, ceramic, dielectric, optical, PTFE etc. at low cost. 
 

Specification

 
Input Power 220VAC 50/60Hz, single phase
2000W (including pump)
Source Power Two sputtering power sources are integrated into one control box
DC source: 500W for coating metallic materials
RF source: 600W with automatching for coating non-metallic materials ( Center)
Compact 300 RF source is available at extra cost
Magnetron Sputtering Head Two 2" Magnetron Sputtering Heads with water cooling jackets are included
One is connected to RF power supply for no-conductive materials
Another is connected to DC sputtering power source for coating metallic materials
Target size requirement: 2" diameter
Thickness Range: 0.1 - 5 mm for both metallic and non-conductive targets
One stainless steel and one Al2O3 ceramic targets are included for demo testing
Head Water Cooling: 10ml/min water flow required, and one 16ml/min digitally controlled recirculating water chiller is included for cooling both magnetron sputtering heads
Customized coater: Two DC head without, RF sputtering, RF head without DC sputtering, 3 RF head are available upon request
Vacuum
Chamber
Vacuum Chamber: 300 mm Dia x 300 mm height, made of stainless steel
Observation Window: 100 mm diameter
Hinged type cover on top with air spring sport makes target exchange easy
Sample Holder Sample holder size: 140mm dia. for. 4" wafer max 
(also can be designed as your requirement)
Sample holder rotation speed is adjustable: 1 - 20 rpm for uniform coating
The holder temperature is adjustable from RT to 500°C Max with accuracy +/- 1.0 °C
Gas Flow
Control
Two precision digital MFC (mass flow controller) are installed to allow two types of gases to be filled in
Flow rate: 200 ml/min max.
Flow rate is adjustable on the 6" touch screen control panel
Vacuum Pump
Station
High speed turbo vacuum pump system (made in Germany) is directly installed on the vacuum chamber for max. vacuum level
Heavy duty dual stage mechanical pump is connected to turbo pump for faster pump speed
Mobile pump station is included and the compact sputtering coater can be put on top of station
Max. vacuum level: 10^-6 torr with chamber baking
Thickness
Monitor
One Precision quartz thickness sensor is built into the chamber to monitor coating thickness with accuracy 0.10 Å
LED Display Unit outside chamber can:5 pcs quartz sensors (consumable) are included
Input material to be coated according to data base included
Display total thickness coated and coating speed
Water cooling is required
Overall
Dimensions
L1300mm× W660mm× H1200mm
Net Weight 160 kg
Warranty One years limited warranty with lifetime support
Application Note In order to remove oxygen from the chamber, suggest you use 5% Hytrogen + 95 % Nitrogen to clan chamber 2-3 times, which can reduce oxygen to below 10 ppm
Please use > 5N purity Argon gas for plasma sputtering. Even though 5N purity Ar, usually contain 10- 100 ppm oxygen and H2O
DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness MonitorDC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor
DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor
Package

DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor

Service

1. Factory prices with the best quality.
2. One year free-of-charge maintenance for all the dental equipment
3. Customized service for special demand
4. Fast and flexible delivery, by sea, by air, by express
5. Quick response within 24 hours
How to order
1. If you are interested in our products, please tell us the model number and quantity.
2. We will make a proforma invoice for your order.
3. We will deliver the product ASAP on receipt of the payment
Guarantee
1. Guarantee for one year after shipment.
Payment
1. Western Union
2. PayPal
3. Secure Payment through Alibaba
4. Telegraphic transfer
5. L/C

Factory

Zhengzhou CY Scientific Instrument Co., Ltd is mainly engaged in the research and development, design, manufacturing and sales of equipment used in scientific researches. Independence and innovation is the company's tenet.Our main products include: tube furnace, muffle furnace, plasma cleaner, vacuum furnace, atmosphere furnace,CVD system and customized lab equipment.Welcome you come to visit us. 


DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor
Exhibition

DC/RF Dual-Head High Vacuum Magnetron Plasma Sputtering System with Thickness Monitor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now